Ganging and Derating Information

WHAT IS GANGING ?

Ganging is the mounting of two or more controls side-by-side in a series of connected wallboxes.

WHAT IS A SIDE SECTION/FIN BREAKOFF?

A scored section along each side of the mounting plate/fin designed to be removed to facilitate ganging.

Ganging and Derating for Lutron Wallbox Dimmers

Vareo, Nova T*, Nova, Centurion - may be ganged without removing the side sections - no derating required. Side sections can be removed to save space or have ganged units fit into existing wallboxes - derating required (side sections must be removed if using VWP Vareo wallplates for Vareo wallplates for Vareo dimmers or tap switches).

Lumea2, Maestro, Diva, Skylark, Ariadni, Faedra, Glyder, Rotary - must remove side sections to gang - derating required.

Athena - no removable side sections - no derating required when ganged.

WHAT IS DERATING?

The reduction of the maximum capacity (load) a dimmer can reliably handle when the side sections (fins) are removed.

 

Planning a Multigang Installation

STEP 1

Determine if the side sections are to be removed or to remain intact (applicable to Vareo, NovaT*, Nova, Centurion).

Consider: width of application, load, number of wallboxes required, product type and side section breakoff options

Control Widths (for determining width of a ganged installation)

Control Size Width 
  Side Sections Intact  One Side Removed Two Sides Removed 
Small 2 3/4"  2 1/4" 1 3/4" 
Large 4 1/2"  4 1/8" 3 5/8" 
  • All Vareo models are considered "small" controls
  • For control sizes of Nova T* and Nova dimmers:
    • 600W and 1000W models are "small" controls
    • 1500W and 2000W models are "large" controls
  • For control sizes of Centurion and Athena dimmers
    • 600W and 1000W models are "small" controls
    • 1500W and 2000W models are "large" controls
  • All Lumea2, Maestro, Diva, Ariadni, Faedra, Glyder and Rotary models are considered "small" controls

STEP 2

Use the capacity derating charts to determine maximum permissible loads for each control in the installation if side sections will be removed.

STEP 3

Determine number of wallboxes required and plan control placements in gang (see charts below):

WALLBOXES REQUIRED - All side sections intact

  Number of Small Controls 
Number of Large Controls 1 3 5
0 0 1+1* 4+1* 7+1*
1 1 5 8 11
2 4 7 10 12  13
3 6 10 11  13 14  16
4 9 11  12 14  15 17  18

*Note: When ganging an even number of small controls with no side sections removed, use wallboxes with tapped ears as shown below. Do not use plastic rings or gangbox covers. Space an additional wallbox 3/4" apart from the other wallbox(es). A 3/4" chase nipple is recommended as a spacer between the wallboxes.

Example: wallbox arrangement required for gang of 4 small controls, side sections intact:

Assembling the Controls

When ganging any combination of small and large controls, place a small control on one extreme end of the gang, and a large control at the other end of the gang. Use center and offset mounting holes as necessary.

WALLBOXES REQUIRED - All inside sections removed

  Number of Small Controls 
Number of Large Controls 1 3 5
0 0 2 4 6
1 1 4 6
2 3 6 8 10
3 5 8 10 11  12
4 7 10 11  12 13  14

Removing Inner Side Sections

When removing side sections, remove only inner side sections. Do not remove side sections on outer ends of the gang.

Assembling the Controls

When ganging any combination of small and large controls, place a small control on one extreme end of the gang and a large control at the other end of the gang. Use center and offset mounting holes as necessary.

STEP 4

Determine the multigang wallplate requirements (Vareo, NovaT*, and Nova).

Click here for the wallplate configurator.

Capacity derating charts

 

Vareo1,2 and Nova T*1,2 Products

     
CONTROL TYPE No side sections removed (full capacity)  One side section removed  Middle unit has two side sections removed 
DIMMERS MAXIMUM CAPACITY 
Incandescent 600W  500W 300W 
1000W 900W  700W
1500W 1250W 1000W
1950W 5 -- --
Magnetic Low Voltage 600VA 500VA  300VA
(450W) (400W)  (250W)
1000VA 900VA  700VA
(800W) (750W)  (500W)
1500VA 1250VA  1000VA
(1200W)  (1000W) (800W) 
Electronic Low Voltage 300W  300W 250W 
600W 500W 400W
Fluorescent
  Hi-Lume/ Eco-10 (ECO Series)      
  Vareo 20 Ballasts/ 8 A 20 Ballasts / 6A 20 Ballasts / 4.5A
  Nova T* 6A No derating required No derating required
8A No derating required No derating required
16A No derating required No derating required
Eco-10 (TVE Series) 0-10 VDC 60 ballasts / 16A No derating required No derating required
Tu-Wire 3 5A 4A 3.3A
FAN-SPEED CONTROLS  
Quiet Controls4 1.5A  1.5A 1.5A 
Fully Variable Controls 6A 4.2A  2.5A
12A 10A  8.3A
Electronic Tapswitches6 1000W/VA  800W/VA 650W/VA
1 Controls must have side sections removed to gang if using "VWP Series" wallplates
2 Recommended minimum 40 watt load
3 Minimum capacity: 2 ballasts/2.5 A
4 For use with only one ceiling paddle fan; prevents motor hum
5 For NT-2000 only.  Do not break fins/side sections
6 VETS-R auxiliary electronics do not require derating

 

Nova and Centurion Products

     
CONTROL TYPE No side sections removed (full capacity)  One side section removed  Middle unit has two side sections removed 
DIMMERS MAXIMUM CAPACITY 
Incandescent 600W  600W 500W 
  1000W 900W  700W
  1500W 1250W  1000W
  2000W 1800W  1500W
Magnetic

Low Voltage

600VA 600VA  500VA
  (450W) (450W)  (400W)
  1000VA 900VA  700VA
  (800W) (750W)  (500W)
  1500VA 1250VA  1000VA
  (1200W)  (1000W) (800W) 
  2000VA 1800VA  1500VA
  (1600W)  (1500W) (1200W) 
Electronic Low Voltage 450W  400W 350W 
Fluorescent Nova controls may be used with either Lutron Hi-lume electronic dimming ballasts or magnetic dimming ballasts. Controls used with electronic dimming ballasts do not require derating. 
FAN-SPEED CONTROLS  
Fully

Variable Controls

6A 5.5A  5A
  12A 11A  10A

Athena controls may only be ganged with side sections intact and do not require derating.

Ariadni, Diva, Diva Satin Colors, Faedra1

Glyder, Luméa2, Maestro1, RadioRA, Rotary,

Spacer1, and Spacer System1

     
CONTROL TYPE No side sections removed (full capacity)  One side section removed  Middle unit has two side sections removed 
DIMMERS MAXIMUM CAPACITY 
Incandescent2 600W  500W 400W 
1000W 800W  650W
Dual Slide Dimmers 300W/300W  250W/250W 200W/200W 
Magnetic Low Voltage2 600VA 500VA 400VA
(450W) (375W)  (300W)
1000VA 800VA  650VA
(800W) (650W)  (500W)
Electronic Low Voltage 300W  250W 200W 
600W 500W 400W
Fluorescent
Hi-Lume/ Eco-10 (ECO and TVE Series) 20 Ballasts / 6 A No derating required No derating required
8A No derating required No derating required
Tu-Wire 5A 4A 3.3A
FAN-SPEED CONTROLS  
Quiet Controls4 1.5A  No derating required No derating required
Fully Variable Controls5 5A 4A  3A
10A cannot gang  cannot gang
FAN/LIGHT CONTROLS  
Quiet Controls4  
Skylark 1.5A/360W  No derating required  No derating required 
Skylark 1.5A/300W  No derating required  No derating required 
Lumea2 1.5A/600W  No derating required  No derating required 
Fully Variable5  
Skylark 5A/360W  4A/360W 3A/360W 
Skylark 2.5A/300W  2.1A/250W 1.7A/200W 
Electronic Switches
RadioRA 8A 6.5A 5A
Spacer System 6A 5A 3.5A
1 Accessory dimmers/accessory switches for Spacer System, Spacer, RadioRA, Faedra, and Maestro Smart Remotes do not require derating.
2 Minimum loads:  40W for Maestro, Faedra, and Spacer dimmers; 60W for Spacer System dimmers, 50W for RadioRA dimmers
3 Minimum capacity: 2 ballasts, 2.5A
4 For use with one ceiling paddle fan; prevents motor hum
5 Total fan plus light load may not exceed 2.5A

Loading...